A 32.85 kW AC rooftop solar system serving AzureGreen’s retail and e-commerce warehouse campus in Middlefield, Massachusetts.
Image: Google Maps satellite view · Imagery ©2026 Airbus, Maxar Technologies
Project brief
NuWatt completed a 32.85 kW AC solar project at AzureGreen in Middlefield, MA, in 2016. The documented mounting system is South-facing pitched-roof rail mount. The project was delivered under a direct-purchase structure.
Design response
Integrate a commercial array into a new garage roof and satisfy the utility witness-test, protection, disconnect, and metering requirements.
Use the unshaded true-south roof plane with three SolarEdge inverters, module-level power optimizers, a revenue-grade meter, and utility-approved protection settings.
At a glance
On site
Installation photography and site context from the project record.
NuWatt completed a 32.85 kW AC solar project at AzureGreen in Middlefield, MA, in 2016. The documented mounting system is South-facing pitched-roof rail mount. The project was delivered under a direct-purchase structure.
The structural review cleared the roof trusses without reinforcement and specified a Unirac SolarMount rail system with staggered EcoFasten attachments at 48 inches on center.
The documented mounting system is South-facing pitched-roof rail mount on 28.4-degree composition-shingle roof.
Use the roof estimator to begin with the building, roof constraints, and usable area before requesting a full engineering assessment.